Delivered reports include labeled photos for every area and finding. Photos are omitted from this sample to protect the tenant's and owner's privacy.
Owner action plan
Immediate Attention
Repair the leak at the bathroom 2 drain P-trap, replace the corrugated drain pipe with a standard trap and drain assembly, and check the vanity floor for moisture damage.
Have a licensed plumber or HVAC contractor evaluate and correct the water heater venting at the ceiling, test the wrapped section before it is disturbed, and repair the water-damaged closet ceiling and walls.
Medium Priority
Have an HVAC contractor clean and treat the microbial growth on the air handler cabinet and PVC piping and replace the rusted cabinet fasteners.
Have a foundation contractor evaluate the exposed rebar and washouts, regrade around the foundation wall, and seal the hairline cracks and chipped corner.
Have a roofer repair the patched shingles, rusted vent flashing and exposed fasteners, separated edge flashing, cracked fascia and worn low-slope roof covering.
Have an electrician replace the broken garage switch cover and evaluate the rust on the electrical panel cabinet.
Have the utility or a plumber evaluate the rust on the gas meter piping.
Repair the open mortar joint, replace the worn sealant at the window sills and frames, and repair the cracked exterior panel above the window trim.
Replace the corroded washer supply valves.
Schedule a chimney sweep for the soot buildup and rust in the firebox.
Clean the dust and debris at the air filter housing and replace the filter.
Low Priority
Repair the lifted plank flooring seams in the living room, kitchen and den.
Replace the worn garage door bottom seal.
Clean the dark staining at the den window sill and frame.
Repair the ceiling damage around the living room supply register and repaint the old water stains on the ceilings from the previous duct leaks, after confirming the areas are dry.
Findings by area
Exterior Follow-up
- Hairline cracks in the foundation (observed in multiple locations).
- Chipped concrete at the foundation corner.
- Washouts and soil depressions around the foundation wall.
- Exposed rebar.
- Open mortar joint in the brick.
- Worn sealant at the window sills and frames (observed in multiple locations).
- Vertical crack in the exterior panel above the window trim.
- Rust on the gas meter piping.
- Rust on the electrical panel cabinet.
- Patched, mismatched shingles near the vent pipe.
- Cracked fascia and trim at the roof edge of the low-slope section.
- Worn, patched areas on the low-slope roof covering.
- Separated metal edge flashing at a corner.
- Rusted vent flashing.
- Rusted and exposed shingle fasteners.
Garage Follow-up
- Broken switch cover plate, with the switch painted over.
- Worn seal at the bottom of the garage door.
Living room Follow-up
- Brown ceiling stains (observed in multiple locations).
- Damage at the ceiling around the supply register.
- Gap at the plank flooring seam.
- Soot buildup and some rust in the firebox.
Kitchen Follow-up
- Lifted seams in the plank flooring.
Den Follow-up
- Lifted seam in the plank flooring.
- Dark staining at the window sill and frame.
Hallway and bedrooms OK
Bathrooms Follow-up
- Leak at the drain P-trap.
- Corrugated pipe used as a drain.
- Mineral buildup at the P-trap slip joint, with staining and dark spotting on the vanity floor.
Laundry Follow-up
- Corrosion and mineral deposits at the washer supply valves.
HVAC Follow-up
- Rusted cabinet fasteners.
- Microbial growth on the cabinet and PVC piping.
- Dust and debris at the filter housing.
Plumbing Follow-up
- Water staining on the ceiling around the flue.
- Non-standard flue connection at the ceiling, with a wrapped section of unknown material.
Electrical OK
Pets Noted
This sample is a rental condition inspection for property management purposes. It is not a TREC Property Inspection Report (REI 7-6) for a real estate transaction. The address, tenant, owner and unit details have been removed; the findings and action plan are shown as written.